Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
Braz. dent. j ; 31(6): 657-663, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132344

ABSTRACT

Abstract The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.


Resumo O objetivo do estudo foi avaliar o efeito de soluções higienizadoras sobre a força de retenção de encaixes do tipo o-ring. Foram avaliadas quatro soluções: Cepacol (C); Cepacol com flúor (CF), Listerine (L), hipoclorito de sódio 0,05% (HS) e água deionizada (controle/AD) em o-rings de nitrilo. Matrizes contendo dois implantes e pilares e espécimes em acrílico com as cápsulas metálicas foram obtidas e divididas entre os grupos. Foi realizada a simulação de 90 imersões noturnas (8 h), sendo obtido o valor da resistência à tração no início e a cada 30 dias (T0, T1, T2 e T3) por meio da máquina de ensaios mecânicos (n=6). Microscopia eletrônica de varredura (MEV) foi utilizada para análise de danos na superfície do o´ring após a imersão (n=1). Para análise estatística dos resultados foi utilizada análise de variância (ANOVA) e múltiplas comparações com ajuste de Bonferroni (poder do teste=1,000; a=0,05). Houve diferença significante para os fatores tempo (p<0,001), solução (p<0,001) e para interação de tempo × solução (p<0,001). Considerando-se os tempos de cada solução, apenas AD não apresentou perda significativa de retenção ao longo do tempo. Comparando as soluções em cada momento, não houve diferença entre as soluções em T0. A partir de T1, CF e HS propiciaram menor retenção quando comparados à AD (p <0,005). Através do MEV foi possível observar alterações nas superfícies dos o-rings de nitrilo imersos em CF e HS. O Cepacol com flúor e hipoclorito de sódio devem ser evitados devido à ação deletéria nos o-rings.


Subject(s)
Sodium Hypochlorite , Tensile Strength , Materials Testing , Denture Retention , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Denture, Overlay
2.
Dental press j. orthod. (Impr.) ; 25(1): 28-35, Jan.-Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1089830

ABSTRACT

ABSTRACT Objective: The purpose of this study was to evaluate the effect of the Yd:YAG laser irradiation on orthodontic bracket base surface. Shear bond strength (SBS) values and sites of the bonding failure interfaces were quantified. Methods: Brackets were divided into two groups: OP (One Piece - integral sandblast base) and OPL (One Piece - laser irradiation). The brackets were randomly bonded on an intact enamel surface of 40 bovine incisors. The SBS tests were carry out using a universal test machine. A stereomicroscopy was used to evaluate the adhesive remnant index (ARI), and surface characterization was performed by scanning electron microscopy (SEM). Student's t-test was used to compare the SBS between the two groups (p< 0.05). Frequencies and chi-square analysis were applied to evaluate the ARI scores. Results: OPL group showed higher value (p< 0.001) of SBS than OP group (43.95 MPa and 34.81 MPa, respectively). ARI showed significant difference (p< 0.001) between OPL group (ARI 0 = 100%) and OP group (ARI 0 = 15%). SEM showed a higher affinity between the adhesive and the irradiated laser base surface. Conclusions: Yd:YAG laser irradiation on bracket base increased SBS values, showing that bonding failure occurs at the enamel/adhesive interface. Laser-etched bracket base may be used instead of conventional bases in cases where higher adhesion is required, reducing bracket-bonding failure.


RESUMO Objetivo: O objetivo do presente estudo foi avaliar o efeito da aplicação do laser Yd:YAG sobre a superfície metálica da base de braquetes ortodônticos, a resistência da colagem ao cisalhamento (RU) e os locais das falhas nas interfaces adesivas. Métodos: Os braquetes foram divididos em dois grupos, de acordo com o tipo de base: OP (One Piece - monobloco, base jateada) e OPL (One Piece - monobloco, base irradiada a laser). Foram selecionados 40 incisivos bovinos hígidos para a colagem de braquetes na superfície do esmalte. Os testes de RU foram realizados por meio de uma máquina de ensaio universal EMIC DL1000. O Índice de Adesivo Remanescente (ARI) e a caracterização das superfícies foram realizados empregando-se estereomicroscópio e microscópio eletrônico de varredura (MEV). O teste t de Student foi aplicado para comparar a RU entre os dois grupos (p< 0,05). O ARI foi avaliado por meio da análise de Frequência e teste do Qui-quadrado. Resultados: O grupo OPL obteve maiores valores de RU (p<0,001) do que o grupo OP (43,95 MPa e 34,81 MPa, respectivamente), e o ARI obteve diferença significativa (p<0,001) entre os grupos OPL (ARI 0 = 100%) e OP (ARI 0 = 15%). A análise proveniente do MEV mostrou alta interação adesiva entre a resina e a superfície metálica da base irradiada pelo feixe de laser. Conclusões: A irradiação com laser Yd:YAG sobre a superfície da base de braquetes metálicos aumentou os valores da RU, demonstrando que as falhas adesivas ocorreram na interface esmalte/adesivo. O uso de braquetes modificados com irradiação a laser pode ser adotado como alternativa aos braquetes com bases convencionais nos casos em que uma maior retentividade for requerida para reduzir as falhas de adesividade.


Subject(s)
Humans , Animals , Dental Bonding , Orthodontic Brackets , Lasers, Solid-State , Surface Properties , Cattle , Shear Strength , Metals
3.
Dental press j. orthod. (Impr.) ; 20(6): 89-96, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-770272

ABSTRACT

Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.


Resumo Objetivo: avaliar os sistemas de força produzidos por quatro marcas de fios de -Ti, dobrados em formas complexas. Métodos: quarenta molas T-Loop (TLS) dobradas à mão, confeccionadas a partir de fios de -Ti, calibre 0,017" x 0,025", foram aleatoriamente divididas em quatro grupos, de acordo com a marca do fio: TMA (G1), BETA FLEXY (G2), BETA III Wire (G3) e BETA CNA (G4). Forças e momentos foram registrados por um transdutor de momento - acoplado a um extensômetro digital, adaptado a uma máquina de ensaios -, a cada 0,5mm de desativação, a partir de 5mm da ativação inicial. A proporção momento-força (M/F), a sobreposição das extensões verticais das TLSs e a relação carga-deflexão (C/D) também foram calculadas. Para completar os resultados, o módulo de Young (MY) de cada fio foi determinado pelo declive no gráfico de carga-deflexão em um ensaio de tração. Ademais, a composição química da superfície foi avaliada por um espectrômetro de fluorescência de raios X por energia dispersiva. Resultados: todos os grupos, exceto o G2, produziram níveis de força semelhantes, inicialmente. O G3 produziu as maiores taxas de C/D, enquanto G1 e G4 tiveram quantidades similares de sobreposição das extensões verticais das TLSs em posição neutra. G1 e G3 geraram os mais altos níveis de momentos, enquanto G2 e G3 produziram os mais altos índices de M/F. Os fios -Ti do G3 produziram o maior MY, e todos os grupos apresentaram composição semelhante, exceto G2. Conclusão: os quatro fios de beta-titânio analisados produziram diferentes sistemas de forças, quando utilizados para formas mais complexas, devido ao fato de que cada fio responde de forma diversa à confecção de dobras.


Subject(s)
Stress, Mechanical , Orthodontic Wires , Titanium , Materials Testing , Dental Alloys
4.
J. appl. oral sci ; 23(6): 571-579, Nov.-Dec. 2015. graf
Article in English | LILACS, BBO | ID: lil-769823

ABSTRACT

ABSTRACT Dental composites cured at high temperatures show improved properties and higher degrees of conversion; however, there is no information available about the effect of pre-heating on material degradation. Objectives This study evaluated the effect of pre-heating on the degradation of composites, based on the analysis of radiopacity and silver penetration using scanning electron microscopy/energy-dispersive X-ray spectroscopy (SEM/EDS). Material and Methods Thirty specimens were fabricated using a metallic matrix (2x8 mm) and the composites Durafill VS (Heraeus Kulzer), Z-250 (3M/ESPE), and Z-350 (3M/ESPE), cured at 25°C (no pre-heating) or 60°C (pre-heating). Specimens were stored sequentially in the following solutions: 1) water for 7 days (60°C), plus 0.1 N sodium hydroxide (NaOH) for 14 days (60°C); 2) 50% silver nitrate (AgNO3) for 10 days (60°C). Specimens were radiographed at baseline and after each storage time, and the images were evaluated in gray scale. After the storage protocol, samples were analyzed using SEM/EDS to check the depth of silver penetration. Radiopacity and silver penetration data were analyzed using ANOVA and Tukey’s tests (α=5%). Results Radiopacity levels were as follows: Durafill VS<Z-350<Z-250 (p<0.05). The depth of silver penetration into the composites ranked as follows: Durafill VS>Z-350>Z-250 (p<0.05). After storage in water/NaOH, pre-heated specimens presented higher radiopacity values than non-pre-heated specimens (p<0.05). There was a lower penetration of silver in pre-heated specimens (p<0.05). Conclusions Pre-heating at 60°C mitigated the degradation of composites based on analysis of radiopacity and silver penetration depth.


Subject(s)
Composite Resins/chemistry , Heating/methods , Hot Temperature , Silver/chemistry , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Reference Values , Spectrometry, X-Ray Emission , Surface Properties , Time Factors , Water/chemistry
5.
RSBO (Impr.) ; 11(2): 178-184, Apr.-Jun. 2014.
Article in English | LILACS | ID: lil-778278

ABSTRACT

Introduction and Objective: Photoelasticity consists of an experimental technique of stress analysis. This technique is very used in most different areas including Dentistry. This literature review presents the several applications of photoelastic technique in Dentistry as well as its advantages and disadvantages. Literature review: Based on this method of analysis, it is possible the verification of the stress distribution and deformation in structures with complex geometry as maxilla and mandible. It can be used to evaluate the distribution of stress on several types of prosthesis as removable partial denture systems with different retention systems, conventional implant prosthesis, overdentures and Brånemark protocols. Moreover, photoelasticity can be used to assess the stress generated by various orthodontic movements, different orthodontic systems and different materials (orthodontic wires). In addition, it is used to analyze different defects of maxillectomy, splint types on traumatized tooth and post-core restoration methods. This technique can also be used to assess dental instruments such as evaluation of different designs of periodontal probe. Conclusion: The photoelastic analysis has been a technique of great importance in health area studies, more specifically in Dentistry. Based on this method of analysis, it is possible to measure the stress distribution and deformation in structures with complex geometry as maxilla and mandible.

6.
Rev. odontol. UNESP (Online) ; 43(1): 46-51, Jan-Feb/2014. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-707254

ABSTRACT

Introdução : O adequado posicionamento tridimensional dos implantes é indispensável para garantir a previsibilidade no tratamento com implantes dentários. Objetivo : Analisar comparativamente o comportamento mecânico do sistema prótese/implante em região anterior de maxila, diferindo os sistemas de encaixe e posicionamento dos implantes. Material e Método : Utilizando um modelo prototipado de maxila, as situações estudadas foram: Grupo IC - implantes nos incisivos centrais e cantilever nos incisivos laterais; Grupo IL - implantes nos incisivos laterais e pônticos nos incisivos centrais; Grupo ICIL - implantes no incisivo central e no incisivo lateral, intercalados com elementos suspensos. Para cada situação estudada, foram utilizadas as três conexões protéticas: hexágono externo, hexágono interno e cone-Morse. O ensaio de ciclagem mecânica foi realizado com a aplicação de 100 N de carga e frequência de 15 Hz no cíngulo dos incisivos a 45° com o longo eixo do dente, para simular o movimento mastigatório. Resultado : No ensaio de ciclagem mecânica, todos os modelos de todos os grupos com os três tipos de conexões protéticas atingiram um milhão de ciclos sem que ocorresse ruptura do parafuso, do componente protético ou da estrutura metálica. Conclusão : Com a metodologia e as condições empregadas, pode-se concluir que o comportamento mecânico das reabilitações implantossuportadas foi semelhante para os diferentes posicionamentos dos implantes e diferentes conexões protéticas. .


Introduction: The adequate three-dimensional positioning of implants is essential to ensure predictability in dental implant treatment. Purpose : Was to comparatively evaluate the mechanical behavior of the system prosthesis/implant in the anterior maxilla, differing the prosthetic connection and the placement of implants. Material and Method: By a maxilla prototyped model the situations were studied: Group IC- implants in the central incisor positions and cantilevers in the lateral incisor positions; Group IL - implants in the lateral incisor positions and pontics in the central incisor positions; Group ICIL one implant in a lateral and one in a central incisor position, with a pontic and a cantilever in the other positions. For each situations were used the prosthetic connections, external hexagon, internal hexagon and Morse-taper. In fatigue test was applied load 100N of frequency 15Hz in the incisors cingulum 45° to the long axis of the tooth to simulate a masticatory movement. Result: After the fatigue test all models of all groups with all three types of connections prosthetic reached 1 million cycles without rupture occurred screw, prosthetic component or metallic structure. Conclusion: According to methodology and conditions studied, can be concluded that the mechanical behavior of the implant-supported rehabilitation was similar to the different positions of the dental implants and the different prosthetic connections. .


Subject(s)
Stress, Mechanical , Dental Prosthesis, Implant-Supported , Dental Implantation , Maxilla , Mouth Rehabilitation
7.
RSBO (Impr.) ; 10(1): 82-88, Jan.-Mar. 2013. tab
Article in English | LILACS | ID: lil-695917

ABSTRACT

Introduction and Objective: The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.

8.
Ortodontia ; 45(1): 25-32, jan.-fev. 2012. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-713851

ABSTRACT

Esta pesquisa avaliou in vitro a resistência ao cisalhamentode bráquetes ortodônticos fotopolimerizados com o arco de plasma, odiodo emissor de luz (LED) e a luz halógena convencional em diferentestempos. Bráquetes foram colados em 60 pré-molares superioreshumanos, divididos em cinco grupos. Nos grupos 1 e 2 utilizou-se a luzarco de plasma por três e seis segundos, respectivamente; nos grupos3 e 4 utilizou-se o LED por cinco e dez segundos, respectivamente; nogrupo 5 utilizou-se a luz halógena por 40 segundos. Os corpos de provaforam armazenados em água destilada em temperatura ambiente e,após 24 horas dos procedimentos de colagem, foram submetidos aosensaios mecânicos na máquina universal MTS-Material Test System. Paraa complementação dos resultados, também foi realizada a avaliação e aclassificação do padrão de descolagem dos bráquetes utilizando o lAR.Os resultados foram analisados por meio da análise de variância (Anova,seguida do teste SNK de Tukey para comparação múltipla de médias.Nãohouve diferenças entre os grupos 2, 4 e 5, as quais foram maioresque as médias dos grupos 1 e 3, iguais entre si. Os escores do lAR nãomostraram diferenças quanto à interface de descolagem entre os trêstipos de luz em todos os tempos testados. A luz arco de plasma e o LEDpodem ser utilizados por tempos reduzidos, dentro de certos limites,em relação à luz halógena na colagem de bráquetes ortodônticos, semperda de resistência ao cisalhamento.


This study evaluated in vitro the shear bond strength ofbraekets bonded with xenon plasma are light, light-emitting diode (LED)and conventional halogen light using different curing times. Bracketswere bonded to the bueeal surfaee of 60 human maxillary premolarsalloeated to tive groups. In groups 1 and 2, the resin was cured with theplasma are for three and six seconds (5), respectively; in groups 3 and4, the LED was used for tive and ten 5, respectively; and in group 5, thehalogen light was used for 40 s. The specimens were stored in waterfor 24 hours and subjected to a shear force until bracket failure. Thedebonding pattern was classified according to the adhesive remnant index(ARI). The results were assessed by Anova and the SNK post-hoe test.No differenees were deteeted among groups 2, 4 and 5, whieh showedhigher averages than groups 1 and 3, whieh were not different betweenthemselves. The ARI scores showed no differenees among the three typesof light sourees in ali times tested. Plasma are and LED lights ean be usedwith shorter euring times, within certain limits, than conventional halogenlight for bonding orthodontie brackets, without decreasing bond strength.


Subject(s)
Curing Lights, Dental , Light-Curing of Dental Adhesives , Lasers, Semiconductor , Orthodontic Brackets , Shear Strength , Bicuspid , Phototherapy
9.
RGO (Porto Alegre) ; 59(3): 445-451, jul.-set. 2011. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-874631

ABSTRACT

Objetivo: Avaliar o conhecimento sobre saúde bucal dos pais e filhos presentes nas comunidades quilombolas localizadas na região do Vale do Ribeira, São Paulo. Métodos: Foram desenvolvidas nas comunidades (André Lopes, Ivaporunduva, Pedro Cubas e Sapatu) atividades educativas e preventivas sobre saúde bucal com as crianças, por meio de palestras, orientações de técnica de escovação, escovação em massa supervisionada, revelação de biofilme dental e aplicação tópica de flúor. Os pais das crianças também participaram das atividades em que foram avaliados sobre a saúde bucal de seus filhos, por meio da aplicação de um questionário padronizado. Além disso, também foi realizada a análise da água de abastecimento das comunidades.Resultados: As crianças apresentaram-se entusiasmadas, receptivas e participativas durante o desenvolvimento das atividades educativas e preventivas. Sobre a aplicação dos questionários, 56,0% dos pais declaram que é ruim a saúde bucal dos seus filhos e 47,2% costumam acompanhar a higienização bucal até os seis anos de idade, aproximadamente, sendo que esse acompanhamento não é frequente.Conclusão: Concluiu-se que pais e filhos quilombolas possuem pouco conhecimento sobre saúde bucal, assim observa-se à necessidade de maior atenção à saúde bucal nessas comunidades, por meio de frequentes ações de educação e promoção de saúde bucal.


Objective: To appraise the oral health knowledge of parents and children from the quilombola communities located in the Ribeira Valley, Sao Paulo.Methods: Preventive and educational activities in oral health were developed with children in the communities (Andre Lopes, Ivaporunduva, Pedro Cubas and Sapatu) including lectures, guidance on tooth brushing techniques, supervised mass brushing, detection of tooth biofilm and topical application of fluoride. Parents also participated in the activities. They were evaluated on the oral health of their children by means of a standard questionnaire. The water supply of the communities was also analyzed. Results: The children participated enthusiastically and responsively in the preventive and educational activities. As to the questionnaires, 56% of parents stated that their children?s oral health was poor and 47.2% of them usually follow up on their children?s oral hygiene until they are approximately six years old, but this follow-up is not frequent. Conclusion: We conclude that quilombola parents and children have very little knowledge about oral health. Therefore increased attention to oral health is required in these communities by means of frequent oral health education and promotion.


Subject(s)
Child , Health Education , Oral Health
10.
RGO (Porto Alegre) ; 59(supl.1): 127-132, Abr.-Jun. 2011.
Article in Portuguese | LILACS | ID: lil-766078

ABSTRACT

O objetivo dessa revisão foi relatar uma visão geral e descritiva a respeito das propriedades de duas soluções irrigadoras, a solução de hipoclorito de sódio e de clorexidina com diferentes concentrações, utilizadas no tratamento de canais radiculares. Uma solução irrigadora considerada ideal deve apresentar ação antimicrobiana, dissolver resíduos teciduais, promover molhamento com finalidade de facilitar a instrumentação, e apresentar biocompatibilidade com os tecidos adjacentes. O hipoclorito de sódio utilizado em diferentes concentrações para limpeza de canais radiculares tem sido a solução de escolha entre os profissionais por apresentar ação antimicrobiana e atuar como solvente tecidual. Porém, atualmente, a clorexidina vem sendo muito utilizada como solução irrigadora devido a propriedades específicas que viabilizam sua utilização, tais como substantividade, efetividade antimicrobiana, e baixa toxicidade. Desse modo concluí-se que a solução de clorexidina com diferentes concentrações se apresenta como uma possível alternativa de solução irrigadora para o tratamento de canais radiculares.


The objective of this review was reporting an overview about the properties of two irrigating solutions, solution of sodium hypochlorite and chlorhexidine, used in the treatment of root canals. A solution must submit irrigating antimicrobial action, dissolve waste tissue, promote wetting to facilitate the instrumentation, and present biocompatibility with the adjacent tissues. The sodium hypochlorite used in different concentrations has been the solution of choice among professionals by presenting antimicrobial action and act as a solvent tissue. However, today, chlorhexidine has been widely used as an irrigating solution due to specific properties that enable its use, such as substantivity, antimicrobial effectiveness, and low toxicity. Thus the solution of chlorhexidine with different concentrations is presented as an alternative to irrigating solution for the treatment of root canals.

11.
Article in Portuguese | LILACS, BBO | ID: lil-561130

ABSTRACT

O objetivo deste trabalho foi avaliar a influência do desenho do implante nas micromovimentações de implantes imediatos com carga imediata. Modelos em elementos finitos de um alvéolo de extração de um incisivo central superior e quatro desenhos de implantes de conexão interna, disponíveis comercialmente (SIN SW®, 3i Certain®, Nobel ReplaceTM e RN synOcta® ITI Standard), com diâmetros e comprimentos semelhantes foram construídos. Cargas de 50, 100 e 200 N foram aplicadas sobre os implantes. ANOVA com nível de 95% de significância foi utilizada para avaliar os dados da micromovimentação dos implantes. O design do implante influencia significativamente (31,21%) a micromovimentação de implantes imediatos com carga imediata. Não obstante, a intensidade da carga aplicada (68,80%) é o fator mais importante na estabilidade dos implantes neste protocolo.


The purpose of this paper was to evaluate the influence of different implant designs on the micromovements of immediately placed implants. CT-based finite element models comprising an upper central incisor socket and four commercially available internal connection implant designs (SIN SW®, 3i Certain®, Nobel ReplaceTM, and RN synOcta® ITI Standard) of comparable diameter and length were constructed. 50, 100 and 200N magnitude loads were applied over the implant. ANOVA at 95% level of significance was used to evaluate bone to implant relative displacement (micromovements). The implant design (68,80%) greatly influences the micromovement of immediately placed implants. However, the loading magnitude (68,80%) is the most important factor regarding the implant stability in this protocol.


Subject(s)
Biomechanical Phenomena , Dental Implants , Osseointegration
12.
Rev. odonto ciênc ; 25(2): 170-173, 2010. tab
Article in English | LILACS, BBO | ID: lil-573163

ABSTRACT

Purpose: This study evaluated the flow rate of the Acroseal, AH Plus, Endomethasone N, Sealapex, and ActiV GP according to the standards of the ISO specification 6876/2001. Methods: A volume of 0.05 mL of the cement mixed according to the manufacturer's recommendations was placed on a glass plate. At 180±5 s after the commencement of mixing, the second glass plate was placed on top of the sealer, followed by the weight of mass approximately 100 g to make a total mass on the plate of 120±2 g. Ten min after the start of mixing, the weight was removed and the value of the diameter of the compressed disc of sealer was measured. The mean of three such determinations for each sealer was taken as the flow of the material. The mean values were compared using ANOVA and Tukey's tests. Results: The results obtained were: Acroseal 21.24 mm, AH Plus 22.72 mm, ActiV GP 24.90 mm, Endomethasone N 18.76 mm, and Sealapex 25.15 mm. Conclusion: Only the Endomethasone N did not conform to ISO Specification that requires that a sealer shall have a diameter of not less than 20 mm. The Sealapex achieved the greatest flow, but it did not differ from Activ GP and AH Plus (P>0.5).


Objetivo: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. Metodologia: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. Resultados: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. Conclusão: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).


Subject(s)
Dental Cements/pharmacokinetics , Root Canal Obturation
13.
Innov. implant. j., biomater. esthet. (Impr.) ; 4(2): 10-16, maio-ago. 2009. ilus
Article in Portuguese | LILACS, BBO | ID: lil-561079

ABSTRACT

Objetivo: o objetivo do presente estudo foi analisar o ambiente biomecânico de implantes imediatos com carga imediata, comparando 3 diferentes magnitudes de carga. Material e Métodos: um modelo em elementos finitos de um incisivo central superior contendo um implante cônico de 13 mm de comprimento e 4,5 mm de plataforma, hexágono interno, foi construído. Elementos de contato friccional foram utilizados para simular as interfaces entre o osso, implante, abutment e parafuso do abutment. Foram aplicadas forças de 50, 100 e 200 N na extremidade superior do abutment. Os dados para a deformação equivalente no osso, as tensões equivalentes no parafuso, deslocamento relativo osso-implante e gap do abutment foram calculados. Resultados/Conclusão: a magnitude das cargas aplicadas sobre os implantes imediatos com carga imediata influenciam significativamente o ambiente biomecânico deste protocolo.


Objective: the purpose of the present study was to evaluate the biomechanical environment of immediately placed implants, by comparing three different loading magnitudes. Material and Methods: a CT-based finite element model of an upper central incisor extraction socket was constructed containing a conical internal hex 13-mm implant. Frictional contact elements were used in the bone, implant, abutment and abutment screw interfaces. Forces of 50, 100 and 200 N were applied on the superior central region of the abutment. Data for the peak equivalent strain in the bone, peak Von Mises stress in the abutment screw, bone-to-implant relative displacement and abutment gap were calculated. Results/Conclusion: the loading magnitudes applied over the implants are capable to greatly influence the biomechanical environment in immediately placed protocol.


Subject(s)
Biomechanical Phenomena , Dental Implants , Osseointegration
14.
Rev. Assoc. Paul. Cir. Dent ; 62(2): 152-156, mar.-abr. 2008. tab, ilus
Article in Portuguese | LILACS, BBO | ID: lil-533580

ABSTRACT

Este estudo objetivou avaliar a influência do tratamento superficial e do uso de silano na resistência adesiva dos reparos com resina composta em cerâmica, utilizando o teste de cisalhamento. Foram confeccionadas 120 amostras de cerâmica, divididas em seis grupos (n=20), de acordo com os diferentes tratamentos de superfície: TI C - ponta diamantada; [TI S] - ponta diamantada e silano; [T2C] - jato abrasivo; [T2S] - jato abrasivo e silano; [T3C] - ácido hidrofluorídrico e [T3S] - ácido hidrofluorídrico e silano. Após o preparo da superfície, o adesivo foi aplicado, foram feitos os reparos com resina composta, os conjuntos termociclados e levados ao cisalhamento. Os dados foram avaliados estatisticamente pela análise de variância (ANOVA) e complementados pelo teste de Tukey no nível de 5% de significância. Constatou-se que houve diferenças estatisticamente significantes na resistência adesiva dos reparos entre os tipos de tratamentos mecânicos da superfície; [TI C] = 19,8; [TI S] = 38,2; [T2C] = 28,9; [T2S] = 38,5; [T3C] = 44,7; [T3S] = 46,4. O tratamento superficial da cerâmica por ácido hidrofluorídrico foi o mais efetivo e o jato e a ponta diamantada iguais entre si, o agente silano tem ação efetiva no aumento da resistência adesiva dos reparos no substrato cerâmico quando preparado com ponta diamantada e jato abrasivo e não sendo efetivo com o ácido.


Purpose: To evaluate the influence of surface treatment and the use of silane on the repair bond strength of composite resin to ceramic using a shear test. Methods: A total of 120 ceramic specimens were fabricated and divided into six groups (n = 20 each) submitted to different surface treatments: [TI C] - diamond bur; [TIS] - diamond bur and silane; [T2C] - air abrasion; [T2S] - air abrasion and silane; [T3C] - hydrofluoric acid, and [T3S] - hydrofluoric acid and silane. After surface preparation, the adhesive was applied and the specimens were restored with composite resin, thermocycled and subjected to shear bond strength testing. The data were analyzed statistically by analysis of variance, followed by the Tukey test, with the levei of significance set at 5%. Results: Significant differences in repair bond strength were observed between the different types of mechanical surface treatment, with [TlC] = 19.8, [TIS] = 38.2, [T2C] = 28.9, [T2S] = 38.5, [T3C] = 44.7, and [T3S] = 46.4. Conclusion: Surface treatment of the ceramic with hydrofluoric acid was the most effective, with no difference between air abrasion and the diamond bur. Silane effectively increased the strength of the repair bond to the ceramic substrate when prepared with a diamond bur and air abrasion, while no effect was observed when silane was combined with hydrofluoric acid. The combination of surface treatment and silane is the best repair technique, with acid conditioning and silane being the method of choice.


Subject(s)
Ceramics , Hydrofluoric Acid , Shear Strength
15.
J. appl. oral sci ; 15(4): 299-304, July-Aug. 2007. ilus, tab
Article in English | LILACS | ID: lil-463682

ABSTRACT

The aim of this study was to assess the influence of a fluoridated medium on the mechanical properties of an internal hexagon implant-abutment set, by means of compression, mechanical cycling and metallographic characterization by scanning electronic microscopy. Five years of regular use of oral hygiene with a sodium fluoride solution content of 1500 ppm were simulated, immersing the samples in this medium for 184 hours, with the solutions being changed every 12 hours. Data were analyzed at a 95 percent confidence level with Fisher's exact test. After the action of fluoride ions, a negative influence occurred in the mechanical cycling test performed in a servohydraulic machine (Material Test System-810) set to a frequency of 15 Hz with 100,000 cycles and programmed to 60 percent of the maximum resistance of static compression test. The sets tended to fracture by compression on the screw, characterized by mixed ruptures with predominance of fragile fracture, as observed by microscopy. An evidence of corrosion by pitting on sample surfaces was found after the fluoride ions action. It may be concluded that prolonged contact with fluoride ions is harmful to the mechanical properties of commercially pure titanium structures.

16.
Article in Portuguese | LILACS, BBO | ID: lil-561052

ABSTRACT

A previsibilidade e o sucesso longitudinal do tratamento por implantes são altamente influenciados pelo ambiente biomecânico ao qual o implante é exposto. A concentração de tensão e deformação pode induzir reabsorção óssea e falhas como desaperto e fratura de parafusos. Neste sentido, o Método de Elementos Finitos tem sido utilizado como ferramenta para avaliação das tensões, deformações e deslocamentos gerados pelas cargas mastigatórias sobre os implantes osseointegráveis, com a finalidade de solucionar problemas estruturais complexos e prognosticar possíveis condições de falha. A expansão da utilização destes métodos é fundamentada em vantagens como custo relativamente baixo, versatilidade e a ausência de mutilações em animais ou humanos, além da confiabilidade comprovada pela larga utilização em diversas áreas do conhecimento. Este artigo tem por objetivo discutir a aplicabilidade do MEF na análise dos aspectos biomecânicos relacionados aos implantes dentais osseointegráveis. Este método foi detalhado didaticamente no que se refere á sua execução e à leitura dos resultados. Foram citados 44 estudos, selecionados no MedlineTM, tendo como critérios de inclusão a relevância do tema, a boa qualidade da metodologia e a importância do periódico onde estão publicados. As palavras-chave utilizadas foram: dental implants, immediate load, finite element, biomechanic e bone loss, em variadas combinações.


The previsibilty and the longitudinal sucess in the treatment with dental implants are highly influenced by the biomechanical conditions of the area where the implant will be installed. The load stress concentration and implant deformation, could facilitate the induction of perimplantar bone resorption as well as some failures and screw fracture. The finite elements method has been used as a tool for this kind of studies, to evaluate tensions, deformations and dislocations caused by masticatory forces on the osseointegrated implants. The finite elements method utilization has expanded in those research works considering its low cost, versatility and the absence of animals or patients, since it is mathematically done as a simulation in the computer. This method of study has acquired credibility in the literature and has been used in many different areas of acknowledgements. The purpose of finite elements method in the present research work is to discuss its applicability in relation to osseointegrated dental implants. It provides detailed results and its execution is not difficult. In the review of the literature 44 studies have been selected and presented considering the subject relevance, emphasizing the method quality and the important periodicals where the studies were published.


Subject(s)
Finite Element Analysis , Biomechanical Phenomena/methods , Dental Implants , Dental Implants/adverse effects , Dental Implants
17.
Acta odontol. venez ; 45(3): 359-362, 2007. ilus, tab, graf
Article in Spanish | LILACS | ID: lil-502093

ABSTRACT

El objetivo de este trabajo fue caracterizar y estudiar el efecto del tratamiento térmico hecho en una aleación metálica de cobre para el uso odontológico, con relación a su comportamiento frente a la corrosión, en un medio que simula la agresividad del ambiente bucal. La caracterización de la aleación fue hecha por medio de análisis de la composición química y microscopia óptica y los ensayos de corrosión comprendieran en la obtención de las curvas de polarización potenciostáticas en solución arenosa de ácido cítrico 1g/L. De acuerdo con los resultados obtenidos se observó que la aleación cuando sometida al tratamiento térmico, sufre una transformación de la estructura dendrítica para una estructura con fases bien definidas. En relación al proceso corrosivo, se verificó por medio de las curvas de polarización potenciostáticas que no ocurre pasivacíon, bien como no ha diferencia en la resistencia a la corrosión entre las muestras con y sin tratamiento térmico en el medio estudiado.


The aim of this work went characterize and to study the effect of heat treatment in based copper metallic alloy for application in dentistry, with relationship to its behavior before the corrosion, in a solution that simulates the aggressiveness of the oral environment. The characterization of the alloy was made by means of chemical analysis and optical microscopy and the corrosion tests consisted in obtaining the potentiostatic polarization curves, in acid citric solution 1g/L. Analyzing the obtained results it was observed that the alloy when submited to the thermal treatment there is a transformation of the dendritic structure for a phase granular structure. In relation to the corrosive process it was verified by means of potentiostatic polarization curves didn't happen passivation, as well as there were not differences in the resistance the corrosion between the samples with and without thermal treatment.


Subject(s)
Citric Acid/adverse effects , Dental Alloys/chemistry , Corrosion , Copper/chemistry , Brazil , Electrolysis/methods , Metallurgy , Microscopy/methods , Data Interpretation, Statistical
18.
Periodontia ; 16(3): 85-89, set. 2006.
Article in Portuguese | LILACS, BBO | ID: lil-463300

ABSTRACT

O estudo da adesão e colonização bacteriana sobre o titânio é de grande importância, pois são fatores principais na patogenia de infecções em biomateriais. A adesão e colonização bacteriana podem variar de acordo com o biomaterial, tipo de microrganismo, fase de crescimento e propriedades superficiais dos materiais. A rugosidade de superfícies sólidas intraorais também tem uma influência na adesão bacteriana. Regiões com uma alta rugosidade de superfícies acumulam e retém mais placa bacteriana. A rugosidade de implantes dentais à base de Ti c.p. pode ser alterada por meio de corrosão por fluoretos.


Subject(s)
Bacterial Adhesion , Dental Implants , Titanium
19.
RGO (Porto Alegre) ; 53(4): 351-355, out.-dez. 2005. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-436253

ABSTRACT

O objetivo deste trabalho foi analisar comparativamente a resistência à fratura de instrumentos de níquel-titânio acionados a motor, levando-se em consideração a quantidade de voltas que o instrumento realizava antes da fratura verificando, a influência da conicidade, da marca e do calibre dos instrumentos. Foram utilizados duzentos e quarenta instrumentos de níquel-titânio, acionados a motor, com 25mm de comprimento, das marcas Profile (Dentsply/Maillefer - Suíça) e Pow-R (Moyco Union Broach - EUA) nos números 15, 20, 25, 30, 35 e 40, distribuídas nos Grupo I: Pow-R 0.02; Grupo II: Pow-R 0.04; Grupo III: Profile 0.04 e Grupo IV: Profile 0.06. Os instrumentos foram submetidos ao ensaio de torção utilizando um dispositivo que empregava rotação no sentido horário. Esse dispositivo era conectado a uma máquina de ensaios mecânicos (MTS - Material Test System) que permitia determinar a quantidade de voltas de cada lima até ocorrer à fratura. Os valores foram analisados estatisticamente, utilizando um teste paramétrico (Análise de Variância). De um modo geral, para os diferentes números, independentes do grupo a que pertenciam, houve um aumento, em média, do número de voltas com o aumento do calibre do instrumento. Em relação a conicidade dos instrumentos verificou-se uma relação inversa entre esse item e a quantidade de voltas antes da fratura, quando se aumentava a conicidade diminuía a quantidade de voltas. Os instrumentos da marca Pow-R, em geral, foram estatisticamente superiores.


Subject(s)
Materials Science , Root Canal Therapy/instrumentation
20.
Braz. oral res ; 19(4): 272-277, Oct.-Dec. 2005. tab
Article in English | LILACS | ID: lil-421128

ABSTRACT

O objetivo deste estudo foi comparar a resistência à compressão e o limite de fadiga compressiva de três resinas compostas indicadas para dentes posteriores (Filtek P-60, Surefil e Prodigy Condensable) e uma universal (Z-100). Corpos-de-prova cilíndricos (8 mm de altura x 4 mm de diâmetro) foram usados. O teste dinâmico foi realizado usando-se o método escada e a relação entre limite de fadiga compressiva, e resistência à compressão também foi calculada (n = 15). Os dados de resistência à compressão e de limite de fadiga compressiva foram submetidos à Anova e ao teste de Tukey. O compósito Z-100 apresentou maior resistência à compressão (307,20 MPa) que Surefil (266,93 MPa) e Prodigy Condensable (222,08 MPa). A resistência de Filtek P-60 (270,44 MPa) foi similar à de Z-100 e à de Surefil, enquanto Prodigy Condensable apresentou a menor resistência à compressão. No teste de limite de fadiga compressiva, Filtek P-60 mostrou maior valor (184,20 MPa) que Prodigy Condensable (155,50 MPa). Os compósitos Surefil (165,74 MPa) e Z-100 (161,22 MPa) mostraram-se similares a Filtek P-60 e Prodigy Condensable. A relação limite de fadiga compressiva/resistência à compressão foi de 70,01% para Prodigy Condensable, 68,11% para Filtek P-60, 62,09% para Surefil e 52,48% para Z-100. Foi concluído que o compósito universal Z-100 foi mais sensível ao teste dinâmico que os materiais de alta viscosidade.


Subject(s)
Composite Resins/chemistry , Dental Stress Analysis , Dental Restoration, Permanent/methods , Compressive Strength , Composite Resins/standards , Materials Testing , Tensile Strength , Viscosity
SELECTION OF CITATIONS
SEARCH DETAIL